Frequently asked questions

Crosby Straightpoint

Note: Our UK offices are closed from 24th December to 1st January for the festive holiday.

  This email address is being protected from spambots. You need JavaScript enabled to view it.

 UK: +44(0)2392 484491    USA: +1 918 834 4611

A complete guide to show what Crosby SP load cell is compatible with what Crosby SP instrumentation or Crosby SP software.

Download here

product guide

Crosby Straightpoint equivalent products for Hydraulic Line Pull Systems

HYDRAULIC LOADCELLS SP LOAD CELL EQUIVILANTS
Tong line pull systems ATEX Radiolink plus or Wireless Loadshackle
Crane weight indicators ATEX Radiolink plus
Wireline weight indicators ATEX Radiolink plus or Wireless Loadshackle or Running line Dynamometer (TIMH)
Tension load cells Radiolink plus (ATEX)
Compression load cells LoadSafe wireless compression load cell


Intrinsically Safe Load Cells

For line pull systems or tong line pull, in hazardous areas, Crosby SP provides an intrinsically safe ATEX/IECEx certificated Wireless Load Cell range, for use in zones 0,1 & 2.ATEX wireless handheld plus

Each product is built and approved by CSA Group, manufactured in a specifically approved workshop and the electronic components are completely sealed within the casing to prevent any chance of electrical sparks igniting flammable gases while in use on oilfield line pull systems.

Why are SP products more suited than Hydraulic equivalents

SP RLP-ATEX is a great alternative to hydraulic or mechanical dynamometers:

  • Safely monitor away from the load (up to 700m or 2300ft)
  • More accurate
  • No cables
  • Line pull can be shown in lbs/kgs / tonnes or kN
  • User-configurable visual overload alarm
  • Smaller, lighter, more portable
  • Cleaner (no oil)
  • Less individual parts

Crosby Straightpoint’s (SP) world-renowned range of load links, used for load monitoring, is split into three distinct categories:

integral v wireless

  • Wireless tension load link (Radiolink plus) used with Crosby SP's wireless hand control or Bluetooth via iOS or Android device
  • Cabled tension load link (digital dynamometer) with integral display (Loadlink plus
  • Cabled tension load link for use with an SP Handheld controller (Wirelink plus)

SP has designed their wireless load links to not include an integrated display and to include a separate non-wireless range that does.

Here are our reasons why:

1. The display tempts the operator to come closer to the dynamometer and the load to read it – this can compromise the operator’s safety by having them within a dangerous area around the lift. It is better to be at a safe distance away using the remotely connected handheld or smartphone with our Bluetooth apps installed.

2. The onboard display needs extra power to keep it running and so can kill the onboard battery life from 1200hrs to less than 100hrs. Generally, the display is the number one reason for repairs made on the load cell.

3. It is susceptible to damage from knocks from rough handling that can crack the screen or break parts of the internal componentry.

4. Working in hazardous areas, SP has developed the Radiolink plus into an intrinsically safe wireless load cell, with a range of 700m/2300m, ensuring safety at a distance

However, it is advantageous to use a Crosby SP cabled load link (also known as a digital dynamometer) that has an integral display during certain applications such as line tensioning or when the worker needs to be close-up to perform hands-on tasks/operations.

One good specific example would be using one with a tripod lifter where a worker uses a crank to lift the load. By its design the tripod lifter needs a close hands-on operation to use it, allowing the worker to be close enough to the load cell display to read it.  

Why buy from Crosby Straightpoint when there are cheaper alternatives? Here is why...

Often the Crosby SP sales team we are met with the comment: “I have been offered a cheaper one elsewhere.”
So, Crosby SP thought, let’s buy one and test it.
Due to the number of load cells from Asian manufacturers flooding the market, Crosby SP can surmise that enough lifting operators and/or lifting equipment distributors choose to buy from these companies to make such operations worthwhile. Crosby SP feared that many are compromising lifting safety by placing products of lower cost but also inferior standard into the marketplace, not backed by industry-recognised accreditations.
Crosby SP wanted to order a load cell directly from a manufacturer, chosen at random, based in Asia to carry out a comparison test against a closely matched Crosby SP product to determine the differences.

In short, our findings were shocking!

Here is SP's Whitepaper with the full report and to help you with your decision please view this video

Please let us know your name.

Invalid Input

Invalid Input

Invalid Input

Please let us know your email address.

Your email does no match please enter again

Invalid Input

Invalid Input

Once you have sent this form it will instantly reach a Crosby SP representative directly, who will respond to your enquiry by email ASAP. Or if you would prefer a call back please let us know in the message.
Note: Gmail email addresses will not be accepted on this form.